Enter your attic floor and what is up there now, and this tells you how many bags to buy and how deep to blow them.

What you're measuring Updates as you type
A plan of the attic floor and a section through it, showing the insulation already there and the new layer to blow on top, labeled with the measurements entered in the calculator. ATTIC FLOOR, LOOKING DOWN 40 ft 25 ft SECTION THROUGH THE ATTIC FLOOR ceiling below add R-49 17 in 0 in
Attic and target

The target

ENERGY STAR, uninsulated attic: R-30 in zone 1, R-49 in zones 2 and 3, R-60 in zones 4 to 8.
Fiberglass is Owens Corning AttiCat's chart; cellulose is Greenfiber SANCTUARY's. Both are sold for homeowner machines.

What is up there now

Loose pink, yellow or white fibers are fiberglass; small gray flecks of paper are cellulose; pea-size gray granules are vermiculite.
Measure in a few spots with a ruler pushed down to the ceiling, and use the average.
The math, line by line
Attic floor—
Existing insulation—
R-value to add—
Coverage per bag—
Bags, exact—
Blow it to—
Settled depth—
Bags, rounded up—
DRAWN MEASURE & BUY
UNITS SQ FT
SOURCE /SOURCES/#insulation

Shopping list

The aim is one trip. Untick anything you already have, add whatever else the job needs, then take the list with you.

Links to Amazon are paid links. If you buy through one, we earn a commission. Your price is the same. Links to Ace Hardware, Home Depot, Lowe's and Menards earn us nothing.

What to buy

Nothing here is listed unless the calculator above says you need it.

  • The fiberglass count above is read off the AttiCat coverage chart. A different fiberglass product has its own chart on the bag, and its count will differ.

  • The cellulose count is read off Greenfiber SANCTUARY's chart. Cellulose takes far more bags for the same R-value, so check which one you priced.

  • The chart requires a minimum depth as well as a minimum bag count. Rulers stapled to the joists show when you have reached the depth above.

Gear for the job

The calculator does not count any of this. Tick what you do not already own.

  • Blowing fiberglass or cellulose fills the attic with fine dust.

  • Sealed goggles keep out the loose fibers that drift in around the sides of glasses.

  • They hold the new layer back from the soffit vents, which ENERGY STAR says must never be covered.

  • Both hands stay free for the hose, and attic lighting rarely reaches the eaves.

  • Step only on joists or a board across them. A foot between joists goes through the ceiling below.

Your own items

    R-49 on each maker's coverage chart

    Owens Corning AttiCat (fiberglass) 39.9 sq ft per bag 17 in installed; homeowner machine
    Owens Corning ProCat (fiberglass) 46.4 sq ft per bag 16.5 in; contractor product
    Johns Manville Climate Pro B-7700 44.6 sq ft per bag 17 in; professional equipment
    CertainTeed InsulSafe SP 42.6 sq ft per bag 18.25 in; truck-mounted machine
    Greenfiber SANCTUARY (cellulose) 14.1 sq ft per bag 13.3 in settled; 25 lb bag

    Square feet one bag covers at R-49, read off each manufacturer's FTC-required chart. Only AttiCat and SANCTUARY are charted on homeowner rental machines; the other three are charted on contractor equipment, which is why they cover more per bag.

    The thing worth knowing

    Every maker's coverage chart puts R-49 over 1,000 sq ft at 22 to 26 bags of blown fiberglass. Calculators that multiply depth by a flat R-per-inch say 48 to 67. The chart is the figure federal law makes the maker print on the bag, and it is the only one worth buying from.

    How to estimate attic insulation

    Blown-in insulation is bought by the bag, and every bag on the shelf carries a coverage chart that says how many square feet one bag covers at each R-value. Federal rules require it. The whole estimate is reading the right row of that chart and dividing.

    R-value to add = target R-value − (existing depth × R per inch)
    bags = attic floor area ÷ square feet per bag at that R-value, rounded upThe FTC's R-value rule, 16 CFR 460.12(b)(2), requires every loose-fill label to state "the minimum settled thickness, initial installed thickness, maximum net coverage area, number of bags per 1,000 square feet" at each R-value.

    Measuring the attic floor

    Measure the floor you will cover, which on a single-story house is close to the house's outside footprint. On a two-story house it is the ceiling of the top floor only. Leave out a garage unless it is heated and you mean to insulate over it. Odd shapes go in as rectangles added together.

    Choosing the target

    ENERGY STAR's current table, based on the 2021 International Energy Conservation Code, recommends R-30 for an uninsulated attic in climate zone 1, R-49 in zones 2 and 3, and R-60 in zones 4 through 8. The zone map is on the same ENERGY STAR page.

    Counting what is already there

    You only buy for the difference. ENERGY STAR's method for the existing layer is to measure its depth and multiply by a figure for the material: 2.5 for loose fiberglass, 3.2 for fiberglass batts, 2.8 for rock wool and 3.7 for cellulose. Six inches of old batts works out to about R-19, so reaching R-49 means adding about R-30.

    That multiplication is an estimate, and it is the only part of this page that uses one. Old insulation compresses and gets disturbed, so measure in several places and use the average. New insulation is not estimated that way. Its R-value comes from the chart.

    Reading the chart

    Owens Corning's AttiCat chart, the fiberglass product sold for homeowner rental machines, gives 39.9 square feet per bag at R-49, blown 17 inches deep. Greenfiber's SANCTUARY cellulose chart gives 14.1 square feet per bag at R-49, installed at 14.3 inches and settling to 13.3. Fiberglass charts list installed and settled depth as the same number because, in Owens Corning's words, "settling is negligible". Cellulose settles about 7 percent, so its chart shows both.

    The chart is a minimum in two ways at once. Owens Corning states that failing to provide both the required number of bags and at least the minimum thickness will result in a lower R-value. Hitting the depth with fewer bags means the layer is fluffier than tested. Using all the bags at a thinner depth means it is packed too tight. The depth rulers in the buy list are how you check the second half.

    The rounding trap

    Charts print two columns that look like the same thing: bags per 1,000 square feet, and square feet per bag. On AttiCat at R-49 the first column says 25. Dividing 1,000 by 39.9 says 25.06, which means buying 26. The coverage column is the more exact one, so this page divides by it and rounds up.

    Between the rows

    A target of R-49 over R-19 already in place means adding R-30, which is a chart row. Other combinations land between rows. Here the page interpolates in a straight line between the two nearest rows, for both bags and depth. That step is ours; the manufacturer does not publish it. The error is small because the charts change smoothly from one row to the next.

    Why other calculators disagree

    For R-49 over 1,000 square feet, the coverage charts of four fiberglass makers say 22 to 26 bags. We tested calculators that instead convert R-value to a depth with a flat R-per-inch figure, then convert depth to volume, then guess a bag yield. They said 48 and 67 bags. Three approximations stacked on each other drift a long way. The FTC rule tells professional installers the same thing when they write up a job: use the data the manufacturer gives you, and "do not multiply the R-value for one inch by the number of inches you installed."

    Fiberglass or cellulose

    The bag counts are not comparable. Cellulose bags hold denser material, so the same attic at R-49 takes 26 bags of AttiCat and 71 bags of SANCTUARY. Compare them by price per square foot covered. The cost field above multiplies whatever price you type by the count for the product you picked.

    A quick cost check

    A 1,000 square foot attic with nothing in it, going to R-49 with AttiCat, is 26 bags. At $40 a bag that is $1,040. With 6 inches of old batts already there, about R-19, the amount to add drops to about R-30, which the chart covers at roughly 69 square feet per bag: 15 bags, or $600.

    Common estimating mistakes

    • Buying for the full target over existing insulation. Subtract what is there first.
    • Using bags per 1,000 instead of square feet per bag. The rounded column can leave you a bag short.
    • Blowing to depth with too few bags. The chart requires both numbers.
    • Mixing up two products' charts. Each product has its own. The count on this page belongs to the product named next to it.
    • Converting through R-per-inch. Use the chart for new material and keep R-per-inch for estimating the old layer.

    When to call a pro

    Several attic conditions are not estimation problems. The EPA says to assume vermiculite insulation contains asbestos and not to disturb it, which rules out blowing anything over it. ENERGY STAR lists knob-and-tube wiring as a fire hazard in contact with insulation, along with wet insulation, mold, rot, and bathroom or dryer vents that exhaust into the attic, as reasons to consult a professional before starting. Keep insulation at least 3 inches from recessed lights unless they are rated for contact, never cover soffit vents, and keep the clearances around flues and chimneys that your local code requires. If any of those apply, a home energy auditor or insulation contractor should look before you buy.

    Questions

    How many bags of blown-in insulation do I need?

    Divide the attic floor area by the square feet per bag that the product's coverage chart gives for your target R-value, then round up. Owens Corning's AttiCat chart gives 39.9 square feet per bag at R-49, so a 1,000 square foot attic needs 25.06 bags, which means buying 26. Greenfiber SANCTUARY cellulose covers 14.1 square feet per bag at R-49, so the same attic needs 71.

    How deep should blown-in attic insulation be?

    As deep as the chart says for the R-value, and never less. AttiCat fiberglass reaches R-49 at 17 inches. SANCTUARY cellulose reaches it at 14.3 inches installed, settling to 13.3. The chart requires both the bag count and the depth: Owens Corning states that falling short on either one lowers the R-value.

    Can I blow new insulation over old insulation?

    Yes. ENERGY STAR says you do not have to use the same type that is already there; if you lay batts over loose fill, they should be unfaced. Work out the R-value already in place by multiplying its depth by ENERGY STAR's figure for that material, subtract it from your target, and buy only for the difference. Vermiculite is the exception: the EPA says to treat it as if it contains asbestos and not disturb it.

    What R-value should my attic have?

    ENERGY STAR's current table, based on the 2021 International Energy Conservation Code, recommends R-30 for an uninsulated attic in zone 1, R-49 in zones 2 and 3, and R-60 in zones 4 through 8. If you already have 3 to 4 inches, it lists R-25, R-38 and R-49 to add for the same zones.

    Why do some calculators say twice as many bags?

    They convert R-value to a depth with a flat R-per-inch figure, convert depth to volume, and guess a bag yield. That compounds three approximations. The manufacturer's chart, which federal rules require on every loose-fill product, measures bags per area directly. For R-49 over 1,000 square feet, the charts of four fiberglass makers say 22 to 26 bags; two R-per-inch calculators we tested said 48 and 67.